Açıklama
General features
Protection degree:
IP65 according to EN 60529
Cover, position 1:
1 pushbutton green 1NO+1NC
Cover, position 2:
1 pushbutton red 1NO+1NC
Housing:
Metal housing, three threaded M20x1,5 conduit entries
Head:
Rotating head with lock auxiliary release device
Working method:
D working method, locked actuator with de-energized solenoid
Inputs and outputs:
2 safety inputs IS1-IS2,
2 safety outputs OS1-OS2,
1 signalling output O3: actuator inserted,
1 signalling output O4: actuator locked,
I4 or IE1-IE2 inputs for solenoid activation,
1 input I3: actuator programming / reset,
1 feedback input EDM I5
2 safety outputs OS1-OS2,
1 signalling output O3: actuator inserted,
1 signalling output O4: actuator locked,
I4 or IE1-IE2 inputs for solenoid activation,
1 input I3: actuator programming / reset,
1 feedback input EDM I5
Safety output activation OS:
Activation mode 1: safety outputs active with actuator inserted and locked
Actuator:
Without actuator
Type of connection:
Without connector